The ROSE Construction Method Building Envelope+ has double wall, 2x4 stud construction, with dense pack cellulose insulation (R40) and 8" concrete ICF foundation walls, with 5.5" of closed-cell foam (R27). Primary roofs have raised heel trusses with 24" min cellulose insulation (R60). Secondary roofs, walls, and closure zones have closed-cell spray foam insulation.
A. BASEMENT/LOWER LEVEL
1) Occupied Level (Conditioned) Design
- Buried Wall-R27 ICF construction
- Exposed Wall-R40 (same as upper level walls if wood)
- Slab-on-Grade-R20+
2) Unoccupied Level Design
- Buried Wall-R10 (exterior if plain concrete)
- Buried Wall-R27 (if ICF construction)
- Exposed Wall-R40 (same as upper level walls if wood)
- Exposed Wall-R27 (same as above if ICF)
- Slab-on-Grade-R10
B. FRAMED WALLS
- R40
C. ROOF
- R60
D. WINDOWS
- R3.5-R5
E. DOORS
- R3-R13